P/N 40688G-47 Waterproof Fuse Kit
Installation Instructions
P
arts/Tools Required
1/8-inch diameter heat shrink tubing
Wire strippers
Crimp tool (Radio Shack P/N 64-409 or equivalent)
Crimp terminals
2-Amp fuse kit
Pr
ocedure
1
. Using a heat gun, install 1/8" diameter heat shrink tubing* over one end of the 4" red wire
(supplied). Install the second piece of 1/8" diameter heat shrink tubing over the red wire on
the C98-20PW Power Cable.
2. Thread red wire of power cord with heat shrink tubing* into one end of fuse holder.
3. Thread the heat shrink end of the 4-inch red wire into other end of fuse holder.
4. Strip insulation on both wires 1/4 inch.
5. Crimp fuse clips to both wires. (Recommended crimp tool Radio Shack No. 64-409 or
equivalent).
6. Insert 2 amp fuse.
7. Snap two halves of housing together.
F
igure B1: Proper assembly of Fuse Holder Kit (40688G-47)
* Note: The heat shrink tubing is
n
ecessary in order to provide
weather tightness.